Technical Update: Expanded High-Speed Capture Support

DELTA-10 supports high-speed event-frame capture across a range of sensor resolutions. Downloadable settings on the High-Speed Preset Downloads page make it easier to choose a frame rate and sensor region for your application.

This technical update highlights the available preset options, followed by setup resources for the Viewer, external signals, and sensor controls.

Choose a resolution and frame rate

The preset catalog is organized by frame rate, with standard, square, and other resolutions listed within each group. Each preset pairs its resolution with the fastest stable setting provided for that region.

Here are a few examples from the catalog:

Frame rateExample sensor resolution
2,200 FPS960 × 720 — full sensor
4,600 FPS640 × 480 — VGA
10,000 FPS352 × 288 — CIF
20,000 FPS200 × 200
30,000 FPS40 × 520
40,000 FPS40 × 200
90,000 FPS40 × 40

The 2,200 FPS full-frame preset is included with DVS Viewer.

The higher frame rates use the listed reduced sensor regions. Open the catalog to see all available resolutions and download the setting that fits the area you need to observe. These preset files are for DELTA-10.

Browse high-speed presets →

Apply a high-speed preset

After downloading the .txt file for your chosen resolution:

  1. Stop the camera stream.
  2. Use the folder button next to Setting to open the settings folder, then copy the downloaded .txt file into it.
  3. Select the file in Setting, apply it, and start the stream.

Changing a preset’s ROI can affect its frame rate. Follow the Sensor Region guide when adjusting the captured area.

Additional setup resources

The documentation also covers the software and connections used alongside the high-speed presets.

Download and use DVS Viewer

The DVS Viewer application shown below is available to download and use with DELTA cameras. The Installation guide provides a Windows installer and Ubuntu installation instructions.

DVS Viewer displaying DELTA-10 event frames with Delta_10_2200FPS.txt selected and the Sensor Settings panel open.

Get DVS Viewer →

Connect external signals

Start with Camera Interfaces to identify the correct connector, pin assignment, and cable wires. For DELTA-10, this includes the M8 connector and the genuine NRV cable wire-color mapping.

The External Signals guides explain how to use:

  • External Trigger: align capture with an input signal using Single, Burst, or Burst single mode.
  • Output Signals: send Global hold, Global reset, Frame start, or Frame end timing pulses through Trigger Out.
  • External Clock: switch DELTA-10 to an external reference clock.

External Trigger is supported on DELTA-01 and DELTA-10. Output Signals and External Clock are DELTA-10 features.

NRV Docs External Signals page linking to the External Trigger, Output Signals, and External Clock guides.
NRV Docs connects the wiring information with guides for each external-signal function.

Explore sensor controls

The Sensor Controls guides cover three controls available in DVS Viewer on DELTA-01 and DELTA-10:

  • Sensor Flip: change horizontal or vertical orientation, or enable both.
  • Event Output: select ON + OFF, ON only, OFF only, or convert all events to ON.
  • Sensor Region: select the output region with ROI, Crop, and APS scan-area controls.

Stop acquisition and recording before changing sensor controls.

From choosing a faster preset to connecting signals and configuring the Viewer, the NRV documentation provides the guides in one place. Start with the DELTA-10 preset catalog and the Viewer installation guide.